Fig.1 | Fig.2 | Fig.3 |
Fig.4 | Fig.5 | Fig.6 |
Type | Fig | Dimensions(mm) | Strength(N) | Q | AL(nH/N2) | WT | ||||||
A | B | C | D | D1 | E | H | BP40/PC95 | (g/set) | ||||
U40.5×15×13 | 1 | 40.1±0.4 | 15±0.2 | 13±0.2 | 4.5±0.2 | / | / | 5±0.2 | ≥160 | ≥1.1 | ≥500 | 18.2 |
U48.4×13.2×14.8 | 1 | 48.4±0.5 | 14.8±0.2 | 13.2±0.2 | 4.5±0.2 | / | / | / | ≥160 | ≥1.5 | ≥600 | 19.9 |
U55.5×13.2×16 | 1 | 55.5±0.5 | 16±0.3 | 13.2±0.2 | 4.5±0.2 | / | / | / | ≥160 | ≥1.6 | ≥690 | 22.7 |
U60×13.2×15 | 2 | 60±0.5 | 15±0.2 | 13.2±0.2 | 4.5±0.2 | / | / | 4.5±0.2 | ≥160 | ≥1.8 | ≥700 | 23 |
U60.5×12.5×19.3 | 2 | 60.5±0.7 | 19.3±0.2 | 12.5±0.2 | 4.5±0.2 | / | / | 5±0.2 | ≥200 | >1.2 | >720 | 25.4 |
U60.5×13.0×15.4 | 2 | 60.5±0.5 | 15.4±0.15 | 13±0.2 | 4.5±0.2 | 5.3±0.1 | ≥200 | >1.85 | >710 | 25.5 | ||
U63.8×15×16 | 3 | 63.6±0.4 | 16±0.2 | 14.9±0.2 | / | / | 52.5min | 5.3±0.2 | ≥200 | ≥2 | ≥790 | 31.9 |
U73×13.2×14 | 2 | 73±0.7 | 14±0.2 | 13.2±0.2 | 4.5±0.1 | 4.5±0.1 | ≥160 | ≥1.5 | ≥720 | 25.8 | ||
U78.2×13.2×14.8 | 1 | 78.2±0.5 | 14.8±0.2 | 13.2±0.2 | 4.5±0.2 | / | / | / | ≥160 | ≥1.8 | ≥800 | 28.3 |
U78.2×18.8×12.5 | 5 | 78.2±0.7 | 18.8±0.3 | 12.5±0.2 | 4.9±0.2 | 4.5±0.2 | / | 6±0.1 | ≥200 | ≥1.9 | ≥860 | 31.2 |
U78×9.0×18.0 | 1 | 78±0.7 | 9±0.3 | 18±0.3 | 5±0.2 | / | / | 4.5±0.2 | ≥160 | ≥1.8 | ≥800 | 25.8 |
U78.3×24×14 | 6 | 78.3±0.4 | 24±0.3 | 14±0.3 | 10±0.25 | / | 67.3±0.4 | 10±0.25 | / | / | / | 74.5 |
U79.1×16.0×4.5 | 4 | 79.1±0.6 | 16±0.2 | / | 5.8±0.2 | 4.5±0.2 | / | 4.5±0.2 | ≥160 | ≥2.5 | ≥950 | 45 |
U92*22*10 | 1 | 92±1 | 22±0.3 | 10±0.3 | 10±0.3 | 10±0.3 | / | / | / | / | / | 53.9 |
Remark: 1.AL value Testing conditon :1KHz,1V,100Ts.
2.Q value testing conditions: 1KHz,1V,100Ts.
3.Compression strength test conditions: test spacing 40mm, test speed 30mm/mim.
The above is the usually type,We can redesign according to costomer′s request.