Fig.1 |
Type | Fig | Dimensions(mm) | Effective parameter | AL(nH/N2) | WT | |||||||||
A | B/I | C/C1/C2 | D/D1 | D2/G | E | F/H | Ae(mm2) | Le(mm) | Ve(mm3) | BP44 | BP95 | (g/set) | ||
UR50/18/35.8 | 1 | 50±0.7 | 18±0.15 | 35.80±0.5 | 32±0.55 | 17±0.25 | 10.5min | 11±0.2 | 501.9 | 89 | 44669.1 | 10000±25% | 12500±25% | 244 |
UR50/20.25/35.8 | 1 | 50±0.7 | 30.25±0.3 | 35.80±0.5 | 32±0.55 | 17±0.25 | 10.5min | 23.25±0.3 | 501.9 | 134.5 | 67505 | 7600±25% | 9500±25% | 362.5 |
Remark: Testing conditon for AL: 1KHz / 0.3V / 100Ts.
The above is the usually type,We can redesign according to costomer′s request.